FIRMWARE RELEASE NOTES ====================== Products affected: AXIS M3007 Release date: 2015-09-09 Release type: Production Firmware version: 5.70.1.2 File name: M3007_5_70_1_2.bin Preceding release: 5.70.1.1 AMC version: 7.1.2.1-2 Onvif support: Profile S -------------------------------------------------------------------------------- UPGRADE INSTRUCTIONS ==================== The firmware can be upgraded using Axis Camera Management, HTTP or FTP. Please follow the instructions from the user's manual, the web page at http://www.axis.com/techsup/cam_servers/how_to_upgrade.htm or the file named howtoupgrade.txt. Corrections in 5.70.1.2 since 5.70.1.1 ====================================== 5.70.1.2:C01 Fixed ACAP event issues. 5.70.1.2:C02 Trigger data available again. 5.70.1.2:C03 Fixes in SDK's parameter API. 5.70.1.2:C04 Respawned ACAPs now have a working CGI interface. 5.70.1.2:C05 Any user with admin permissions can now edit ACAP settings. 5.70.1.2:C06 Solved recording export issues with DST. 5.70.1.2:C07 Use proper ONVIF bitrate limit. 5.70.1.2:C08 Tilt in panorama view while in desktop mode now possible. 5.70.1.2:C09 Stop losing direction settings after restart. 5.70.1.2:C10 Dynamic text overlay now available on all image sources. Known Bugs/Limitations ====================== 5.70.1.2:L01 To be able to use all parts of the image in a View Area use the 4:3 Aspect Ratio for the View Area. 5.70.1.2:L02 Recording streams to SD Card with a total bit rate above 12Mbit/sec may cause missing frames/sequences. 5.70.1.2:L03 90 and 270 rotation can cause a drop in frame rate. 5.70.1.2:L04 To avoid corrupt recordings, it is recommended to unmount the SD Card before ejecting it. 5.70.1.2:L05 Private keys need to be in a PKCS#1 format in order to function when installing Certificates. 5.70.1.2:L06 For low contrast scenes, false positives or negatives may occur because there is not enough information for the Tampering alarm. 5.70.1.2:L07 Reboot is necessary after changes to SOCKS such as enabling/disabling and parameter changes. 5.70.1.2:L08 When changing an active https-certificate, the product needs to be restarted for the new certificate to be applied. 5.70.1.2:L09 When upgrading to firmware 5.70, the Edge Storage database might take a couple of minutes to migrate to the new database system. Make sure not to remove power or SD card during the first few minutes after upgrading the device. Edge Storage recordings used with 5.70 products will not show recordings when downgraded to previous firmware. The recordings will however still be present on the card but not accessible. 5.70.1.2:L10 Time modifiers used in the field "Create folder" is only used upon activation of the rule, hence no new folders are created with the current time during an active rule. To have new folders created with time modifiers you should add them in the "Base filename". 5.70.1.2:L11 Custom Exposure windows is not visible in Chrome and Firefox. Please use Internet Explorer. 5.70.1.2:L12 To be able to seek in exported mkv recordings you need to use AXIS Matroska File Splitter, see axis.com. Files are playable both with and without AXIS Matroska File Splitter. 5.70.1.2:L13 If setting the video stream resolution to an unsupported value, it's not possible to start streaming without specifying a valid resolution or correcting the video stream resolution to a supported resolution. 5.70.1.2:L14 SNMP OID that have been set are not kept after reboot. 5.70.1.2:L15 Video motion detection will detect objects hidden behind privacy masks. 5.70.1.2:L16 Once "Custom" Exposure Windows is chosen within the Java Exposure applet the browser login window keeps asking for credentials until you use root as login credentials. 5.70.1.2:L17 Pan limits set using VAPIX are not reflected using ONVIF. 5.70.1.2:L18 Using special characters § ½ ! £ \ ” @ [ ] ’ $ ¤ {}& * ? ^¨~+ =´ ` < > | , ; : in the upload folder name will not work as expected. 5.70.1.2:L19 After uploading a new application, the installed applications list web page needs to be manually reloaded for it to be updated. 5.70.1.2:L20 For the Java Applet viewing to work with Java 7 update 51 and later add the camera URL to the exception list as per: http://www.java.com/en/download/help/java_blocked.xml 5.70.1.2:L21 It's not possible to set the RTPS timeout in the URL specifying the stream. The default value of 120 seconds will always be used. Supported AXIS VAPIX API Image Resolutions for AXIS M3007 ============================================================== Resolution Exceptions ========== ========== 2592x1944 2) 2048x1536 2) 1920x1440 4) 5) 6) 1920x1080 6) 1600x1200 2) 4) 5) 6) 1920x720 3) 1280x960 2) 4) 5) 6) 1600x600 3) 1280x720 6) 1024x768 2) 4) 5) 6) 1280x480 3) 800x600 2) 4) 5) 6) 800x450 6) 960x360 3) 640x480 2) 4) 5) 6) 640x360 6) 480x360 2) 4) 5) 6) 640x240 3) 480x270 6) 480x180 3) 320x240 2) 4) 5) 6) 320x180 6) 240x180 2) 4) 5) 6) 320x120 3) 160x120 2) 4) 5) 6) 160x90 6) 2560x1920 1) 2) 768x576 1) 2) 4) 5) 6) 768x288 1) 3) 384x288 1) 2) 4) 5) 6) 384x144 1) 3) 240x135 1) 6) 192x144 1) 2) 4) 5) 6) 192x72 1) 3) 1) Not visible in web user interface 2) Available for Overview view 3) Available for Panorama view 4) Available for Double Panorama view 5) Available for Quad view 6) Available for View area