FIRMWARE RELEASE NOTE ===================== Products affected: P3717-PLE Release date: 2020-01-17 Release type: Production Firmware version: 9.60.1.1 Preceding release: 9.60.1 -------------------------------------------------------------------------------- Upgrade instructions ==================== Upgrade the firmware according to the instructions given at https://www.axis.com/ca/en/support/tecnical-notes/how-to-upgrade or howtoupgrade.txt, which is included in the firmware folder. Features in 9.60.1 ================================================================================ 9.60.1:F1 Added possibility to select stream profile for continuous recordings. 9.60.1:F2 Added possibility to set image rotation in ONVIF media profiles. 9.60.1:F3 Added Geolocation API. See VAPIX documentation for more information. 9.60.1:F4 Added possibility to copy action rules, schedules and recipients. 9.60.1:F5 Updated Video Motion Detection to version 4.4.3. 9.60.1:F6 Added NTP synchronization status to VAPIX Time API. 9.50.1:F1 Added support for setting image frequency in action rules. 9.50.1:F2 Updated Apache to version 2.4.41 to increase overall minimum cyber security level. 9.50.1:F3 Updated OpenSSL to version 1.1.1d to increase overall minimum cyber security level. 9.50.1:F4 Updated Video Motion Detection to version 4.4.2. 9.50.1:F5 Added possibility to disable the web UI to increase overall minimum cyber security level. The web UI can be disabled under System -> PlainConfig -> System -> System Web Interface Disabled. To enable the web UI after it has been disabled, the VAPIX parameter System.WebInterfaceDisabled must be set to "no". Corrections in 9.60.1.1 ================================================================================ 9.60.1.1:C1 Corrected an issue that prevented use of rotation on other than the first view area. Corrections in 9.60.1 ================================================================================ 9.60.1:C1 Corrected an issue that caused the HTTP recipient URL to be cropped. 9.60.1:C2 Corrected the following security vulnerabilities: CVE-2019-13377 CVE-2019-16275 9.50.1.1:C1 Corrected an issue where autofocus sometimes did not work when using the web- interface. 9.50.1.1:C2 Corrected an issue that sometimes caused some of the sensors to be out of focus. 9.50.1:C1 Improved Tampering Detection. 9.50.1:C2 Corrected an issue that could cause the web-interface to freeze upon action rule configuration with Fence Guard. 9.50.1:C3 Improved recording robustness in the event of temporary storage loss. 9.50.1:C4 Increased the limit of concurrent HTTP requests for I/O related VAPIX commands from 4 to 10. 9.50.1:C5 Corrected an issue that caused the stream to be mirrored on the y-axis instead of the x-axis when 90 or 270 degree rotation was configured. 9.50.1:C6 The deprecated parameter HTTPS.AllowSSLV3 has been removed completely now. Known Bugs/Limitations ================================================================================ Supported AXIS VAPIX API Image Resolutions for P3717-PLE ================================================================================ Resolution Exceptions ========== ========== 1920x1080 1280x720 1024x768 1024x640 800x600 800x500 800x450 640x480 640x400 640x360 480x360 480x300 480x270 320x240 320x200 320x180 240x180 176x144 160x120 160x100 160x90 1400x1050 1) 768x576 1) 720x576 1) 704x576 1) 704x480 1) 704x288 1) 704x240 1) 384x288 1) 352x288 1) 352x240 1) 192x144 1) 176x120 1) 96x64 1) 80x50 1) 1) Not visible in web user interface