FIRMWARE RELEASE NOTES ====================== Products affected: AXIS A1001 Release date: 2016-09-09 Release type: Production Firmware version: 1.50.0 File name: A1001_1_50_0.bin Preceding release: 1.46.0 AMC version: None Onvif support: Profile C ------------------------------------------------------------------------------ UPGRADE INSTRUCTIONS ==================== Upgrade the firmware with AXIS Camera Management, HTTP, or FTP. Follow the instructions given in the User Manual, at http://www.axis.com/support/tecnical-notes/how-to-upgrade, or howtoupgrade.txt, which is included in the firmware folder. New Features ============ 1.50.0:F1 Performance improvement for access control management. Known Bugs/Limitations ====================== 1.50.0:L01 //https://trouble/ticket/59584 After a firmware update, the web browser cache may need to be cleared to avoid seeing pages originating from the old firmware. 1.50.0:L02 //https://trouble/ticket/46059 //Internal information //RN from 5.55.3.3 P1405-E,P1425, P1427, //P3215 5.55.3 and 5.55 P1428 //integrated to lfp master R14.16.0 //RS comment: Mention in RN for ALL It's possible to set faulty IP addresses as proxy under AVHS settings. 1.50.0:L03 //https://trouble/ticket/48315 Creating an action rule (on the action engine web pages) with additional conditions (e.g. schedule trigger /and/ door monitor open) does not work. 1.50.0:L04 //https://trouble/ticket/63683 Specifying an IdPoint timeout value (waiting for PIN to be entered) greater than 10 seconds has no effect. 1.50.0:L05 //https://trouble/ticket/64562 When using the API to add credentials with eg. CardRaw fields, where a hexadecimal representation of card data is used, it is important that lower case letters are used. 1.50.0:L06 //https://trouble/ticket/72996 //Internal information No DSCP value when sending QoS packages. 1.50.0:L07 //https://trouble/ticket/78739 In Entry Manager Date & Time Settings you can only input the IP address of the ntp server, not the DNS name. DNS name of NTP server can be provided by going into Additional Controller Configuration > System Options > TCP/IP > Advanced > NTP Configuration. 1.50.0:L08 //https://trouble/ticket/79843 Changing the Time Zone will not work from ACS and ACM. 1.50.0:L09 //https://trouble/ticket/80063 It is not possible to create action rules with schedules, other than "Always (No Schedule)", when in a controller cluster. 1.50.0:L10 //https://trouble/ticket/81858 Using the controllers API setting up a recurring rule without a counter or end date does not work. 1.50.0:L11 //https://trouble/ticket/83060 Creating an Action Rule triggering on Door Monitor with additional conditions or other schedule than Always(no schedule) will not work. 1.50.0:L12 //https://trouble/ticket/83999 Denied access does not show in access log (System Options>Support>Logs and Reports>Access Log) 1.50.0:L13 //https://trouble/ticket/84303 A schedule with a duration shorter or equal to one hour does not show its end time when viewed in "Show in calendar when the schedule applies". 1.50.0:L14 //https://trouble/ticket/88289 If the device is configured with two locks that are operating under scheduled unlock, the locks will lock after a system reboot even if the schedule states that they should be unlocked. 1.50.0:L15 //https://trouble/ticket/90344 When transitioning from the door state LockedDown to door state Locked (via LockedDownReleaseDoor), a door forced open alarm beep on the reader will stop beeping. 1.50.0:L16 //https://trouble/ticket/91151 Importing a JSON file with an invalid hardware configuration will be reported as being successfully imported. 1.50.0:L17 //https://trouble/ticket/92724 The Daylight Savings time setting does not change the time in the Event Log in AEM. 1.50.0:L18 //https://trouble/ticket/93032 When an Aperio system is set up and the hardware configuration is exported, the Aperio Hub is missing in the export. 1.50.0:L19 //https://trouble/ticket/96196 In a system with two configured locks, when a REX button is pressed the event "No action taken by anonymous users after granted access" will show up directly after the "Accessed" event in the event logger. 1.50.0:L20 //https://trouble/ticket/96499 It is possible to add a Door or Floor to the same access group several times in AEM, even if this it is not displayed. When removing the Door or Floor this is not updated properly. 1.50.0:L21 //https://trouble/ticket/99215 When removing a device from a controller cluster that is configured to control an A9188 device, the GUI popup only mentions doors, not floors. 1.50.0:L22 //https://trouble/ticket/99433 If a proper Aperio hardware configuration is completed without any physical doors, the controller GUI might show the text "The hardware on this controller is not configured". 1.50.0:L23 //https://trouble/ticket/99939 The reader feedback indicating door open too long is incorrect. A pulsating beep is heard instead of a constant beep.