FIRMWARE RELEASE NOTES ====================== Products affected: AXIS F41 Release date: 2015-06-05 Release type: Production Firmware version: 5.65.2 File name: F41_5_65_2.bin Preceding release: 5.55.3.2 AMC version: 7.0.8.1-1 Onvif support: Profile S ------------------------------------------------------------------------------ UPGRADE INSTRUCTIONS ==================== The firmware can be upgraded using Axis Camera Management, HTTP or FTP. Please follow the instructions from the user's manual, the web page at http://www.axis.com/techsup/cam_servers/how_to_upgrade.htm or the file named howtoupgrade.txt. New Features ============ 5.65.2:F01 Adds support for new sensor unit. 5.65.2:F02 Sensor unit id and status available in serverreport. 5.65.2:F03 Firmware 5.60 extends the ACAP SDK which gives new possibilities to develop ACAP’s. It is also possible to enable multiple ACAP applications to run simultaneously. 5.65.2:F04 Axis is now extending SNMP with AXIS Video MIB (Management Information Base). The Video MIB enables notification of a number of possible disruptions in Axis products such as fan failure, temperature limits, storage disruptions, tampering, video/audio connectors disconnect, etc via SNMP traps. Available traps depend on the Axis product. A MIB is released for Axis products. See http://www.axis.com/techsup/software/index.htm for more information. 5.65.2:F05 Axis firmware now has the ability to auto-format an SD card to a specified file system upon insertion. This will allow an easy installation of a new SD card that will be formatted automatically to a preselected file system, mounted and recording will be resumed. 5.65.2:F06 Edge Storage recording makes it possible to indicate, e.g. on the Live view, that an edge storage recording is ongoing. This allows the operator to be notified if a recording of scene is ongoing or not. 5.65.2:F07 The Live View page is updated with responsive design and scales with different screen resolutions and browser window sizes. This will allow the user to always see the complete page without the need to scroll. 5.65.2:F08 For all megapixel products, a new default viewing profile for HDTV resolution has been added. This viewing profile is visible in the Live View and is beneficial for demonstration purposes. 5.65.2:F09 The Export Video Clip capability enables the export of recordings directly from the camera to a PC or a smartphone. Select the wanted portion of an Edge Storage recording from your camera and export them as playable video file to a client. The exported recording will be one playable matroska file. 5.65.2:F10 SSH command line interface to the products that may be used for specific support and maintenance activities was introduced in 5.50. SSH is now the only supported protocol to establish a connection and telnet is not supported anymore. SSH is not enabled by default but can be activated by an API. Corrections in 5.65.2 since 5.55.3.2 =================================================== 5.65.2:C01 Fix for AMC with IE10 when using IPv6 is included. 5.65.2:C02 Video performance is no longer affected by ip address filtering. 5.65.2:C03 The camera is not halted in the startup process if a corrupted SD card is present in the SD slot. 5.65.2:C04 The RS232 serial port can now be used in ACAP using axserialport. 5.65.2:C05 Identity Association now present in DHCPv6 SOLICIT messages. 5.65.2:C06 HTTP recipient URL not converted to lower case anymore. 5.65.2:C07 Plugged a socket leak in virtual I/O. 5.65.2:C08 Moved Moscow to GMT+3. 5.65.2:C09 Improved audio detection events. 5.65.2:C10 RTSP session id will not contain % token anymore. 5.65.2:C11 Video loss bit set in trigger data when sensor unit is disconnected. Known Bugs/Limitations ====================== 5.65.2:L01 The ipv6.class field will have the same value in all IPv6 packages. The class field value depends on the value of the DSCP setting. 5.65.2:L02 You can wait more than 60 minutes between activating IDDNS and registering the product on axiscam.net. 5.65.2:L03 Reboot is necessary after enabling SOCKS. 5.65.2:L04 When streaming with the G726 audio codex using bitrate 24kbit/s only distorted audio is heard in the stream. The same distorted audio is heard on the camera output when sending audio to it. 5.65.2:L05 The interval between bonjour probe retries is too short. 5.65.2:L06 You can not trigger digital inputs set to the any setting through the web API. 5.65.2:L07 Private keys need to be in a PKCS#1 format in order to function when installing Certificates. 5.65.2:L08 For low contrast scenes, false positives or negatives may occur because there is not enough information for the Tampering alarm. 5.65.2:L09 When changing active https-certificate, the device needs to be restarted before it becomes active. 5.65.2:L10 Time modifiers used in the field "Create folder" is only used upon activation of the rule, hence no new folders are created with the current time during an active rule. To have new folders created with time modifiers you should add them in the "Base filename". 5.65.2:L11 Custom Exposure windows is not visible in Chrome and Firefox. Please use Internet Explorer. 5.65.2:L12 Longer connection disruptions towards the Network storage during playback of a recording from the Network storage may affect the possibilities to setup new video streaming also some time after reconnection. Ongoing live streaming will not be affected. 5.65.2:L13 The possibility to control individual streams in an aggregate session is removed. This means that a client that starts an RTSP session which includes both audio and video will not be able to pause only one of the medias while the other keeps streaming. If the client needs to do this then it must set up two separate RTSP sessions, one for the audio and one for the video. 5.65.2:L14 To be able to seek in exported mkv recordings you need to use AXIS Matroska File Splitter, see axis.com. Files are playable both with and without AXIS Matroska File Splitter. 5.65.2:L15 If setting the video stream resolution to an unsupported value it's not possible to start streaming without specifying a valid resolution or correcting the video stream resolution to a supported resolution. 5.65.2:L16 SNMP OID that have been set are not kept after reboot. 5.65.2:L17 Once "Custom" Exposure Windows is chosen within the Java Exposure applet the browser login window keeps asking for credentials until you use root as login credentials. 5.65.2:L18 Backlight compensation settings removed. 5.65.2:L19 When upgrading to the firmware 5.60, the Edge Storage database might take a couple of minutes to migrate to the new database system. Make sure to not remove power or SD card during the first few minutes after upgrading the device. Edge Storage recordings used with 5.60 products will not show recordings when downgraded to previous firmware. The recordings will however still be present on the card but not accessible. Supported AXIS VAPIX API Image Resolutions for AXIS F41 ======================================================= Dependent on connected sensor unit, different capturemodes are supported: 1080p sensor units: 1080p 1920x1080 (16:9) @ 25/30 fps (WDR) 1080p 1920x1080 (16:9) @ 50/60 fps (no WDR) WUXGA 1920x1200 (16:10) @ 25/30 fps (no WDR) 720p sensor units: 720p 1280x720 (16:9) @ 30/25fps Resolutions that are in the same for all sensor units: Resolution Exceptions ========== ========== 1280x720 1024x768 1024x640 854x480 800x600 800x500 800x450 640x480 640x400 640x360 480x360 480x300 480x270 768x576 1) 720x576 1) 704x576 1) 704x480 1) 704x288 1) 704x240 1) 384x288 1) 352x288 1) 352x240 1) 240x135 1) 192x144 1) 176x144 1) 176x120 1) 80x50 1) Resolution list applicable to 1080p sensor units Resolution Exceptions ========== ========== 1920x1200 3) 1920x1080 2) 1600x1200 3) 1400x1050 2,3) 1280x960 2,3) 1280x800 2,3) 320x240 2,3) 320x200 2,3) 320x180 2,3) 240x180 2,3) 160x120 2,3) 160x100 2,3) 160x90 2,3) Resolution list applicable to 720p sensor units Resolution Exceptions ========== ========== 320x240 1) 320x200 1) 320x180 1) 240x180 1) 160x120 1) 160x100 1) 160x90 1) 1) Not visible in web user interface 2) Only possible with 1080p sensor units, 1080p 1920x1080 (16:9) @ 60/50/30/25fps 3) Only possible with 1080p sensor units, WUXGA 1920x1200 (16:10)@ 25/30fps 4) Only possible with 720p sensor units, 720p 1280x720 (16:9) @ 30/25fps