FIRMWARE RELEASE NOTES ====================== Products affected: AXIS P1357/-E Release date: 2015-05-28 Release type: Production Firmware version: 5.70.1.1 File name: P1357_5_70_1_1.bin Preceding release: 5.70.1 AMC version: 7.1.2.1-2 Onvif support: Profile S ------------------------------------------------------------------------------ UPGRADE INSTRUCTIONS ==================== The firmware can be upgraded using Axis Camera Management, HTTP or FTP. Please follow the instructions from the user's manual, the web page at http://www.axis.com/techsup/cam_servers/how_to_upgrade.htm or the file named howtoupgrade.txt. Corrections in 5.70.1.1 since 5.70.1 ==================================== 5.70.1.1:C01 It is possible to add domain for the user towards a Network Share. 5.70.1.1:C02 Solve network share mount failures at startup. 5.70.1.1:C03 Passwords can now contain "#". 5.70.1.1:C04 Bluish image effect during dusk and dawn is now neutralized. Use Custom Window white balance option to get the desired behavior. Known Bugs/Limitations ====================== 5.70.1.1:L01 When the automatic IR cut filter enables/disables the IR cut filter, it may trigger motion detection. 5.70.1.1:L02 To be able to use all parts of the image in a View Area, use the same Aspect Ratio for the View Area as for your Capture Mode or Resolution. 5.70.1.1:L03 Recording streams to SD Card with a total bit rate above 12Mbit/sec may cause missing frames/sequences. 5.70.1.1:L04 90 and 270 rotation can cause a drop in frame rate. 5.70.1.1:L05 If max gain is set to a low value, e.g. 0, the IR cut filter may not switch back on automatically. 5.70.1.1:L06 To avoid corrupt recordings, it is recommended to unmount the SD Card before ejecting it. 5.70.1.1:L07 Private keys need to be in a PKCS#1 format in order to function when installing Certificates. 5.70.1.1:L08 For low contrast scenes, false positives or negatives may occur because there is not enough information for the Tampering alarm. 5.70.1.1:L09 Reboot is necessary after changes to SOCKS such as enabling/disabling and parameter changes. 5.70.1.1:L10 When changing an active https-certificate, the product needs to be restarted for the new certificate to be applied. 5.70.1.1:L11 When upgrading to firmware 5.70, the Edge Storage database might take a couple of minutes to migrate to the new database system. Make sure not to remove power or SD card during the first few minutes after upgrading the device. Edge Storage recordings used with 5.70 products will not show recordings when downgraded to previous firmware. The recordings will however still be present on the card but not accessible. 5.70.1.1:L12 Time modifiers used in the field "Create folder" is only used upon activation of the rule, hence no new folders are created with the current time during an active rule. To have new folders created with time modifiers you should add them in the "Base filename". 5.70.1.1:L13 Custom Exposure windows is not visible in Chrome and Firefox. Please use Internet Explorer. 5.70.1.1:L14 To be able to seek in exported mkv recordings you need to use AXIS Matroska File Splitter, see axis.com. Files are playable both with and without AXIS Matroska File Splitter. 5.70.1.1:L15 If setting the video stream resolution to an unsupported value, it's not possible to start streaming without specifying a valid resolution or correcting the video stream resolution to a supported resolution. 5.70.1.1:L16 SNMP OID that have been set are not kept after reboot. 5.70.1.1:L17 Video motion detection will detect objects hidden behind privacy masks. 5.70.1.1:L18 Once "Custom" Exposure Windows is chosen within the Java Exposure applet the browser login window keeps asking for credentials until you use root as login credentials. 5.70.1.1:L19 Pan limits set using VAPIX are not reflected using ONVIF. 5.70.1.1:L20 Automatic gain setting needs to be configured to 42dB for the use of color optimized Day/Night switch priority setting, otherwise night mode will never trigger. 5.70.1.1:L21 Using special characters  « ! œ \ " @ [ ] ' $  {}& * ? ^"~+ =' ` < > | , ; : in the upload folder name will not work as expected. 5.70.1.1:L22 After uploading a new application, the installed applications list web page needs to be manually reloaded for it to be updated. 5.70.1.1:L23 For the Java Applet viewing to work with Java 7 update 51 and later add the camera URL to the exception list as per: http://www.java.com/en/download/help/java_blocked.xml 5.70.1.1:L24 It's not possible to set the RTPS timeout in the URL specifying the stream. The default value of 120 seconds will always be used. Supported AXIS VAPIX API Image Resolutions for AXIS P1357/-E ============================================================== Resolution Exceptions ========== ========== 2592x1944 2) 2048x1536 2) 3) 1920x1080 2) 3) 4) 1600x1200 2) 3) 5) 1280x1024 1280x960 1280x800 2) 1280x720 1024x768 800x600 800x450 640x480 640x360 480x360 480x270 320x240 320x180 240x180 176x144 160x120 160x90 2560x1920 1) 2) 2560x1440 1) 2) 768x576 1) 720x576 1) 2) 704x576 1) 704x480 1) 704x288 1) 704x240 1) 384x288 1) 352x288 1) 352x240 1) 240x135 1) 192x144 1) 176x120 1) 1) Not visible in web user interface 2) 5MP 2592x1944 (4:3) 3) 3 MP 2048x1536 (4:3) 4) HDTV 1080p 1920x1080 (16:9) 5) 2 MP 1600x1200 (4:3)